Обязанности и достижения:
Kontur-West
Moscow
HVAC engineer, Service and E&I
Functions:
Supporting Sales managers and design drafts.
Supervising in installing of duct systems, VRF refrigerant piping, air distribution, installing of rooms temperature or humidity controllers, rooftop systems.
Supervising of installing of control system of swimming pools - filtration, temperature humidity regulation, Ph - control and regulation as like for swimming pools and wet chillers
Designing of AHU and exhaust systems with recuperation and central airs.
Installation, commissioning, modification of as-built documentation and start-up of systems of automation of management of supply and exhaust (Sistemair, Danterm, VTS-clima, CIC, 2VV, Korf, NED, Wesper, Menerga, Technoclima), supply and exhaust with recuperation (Sistemair, Danterm, VTS-clima, Menerga).
Installation, commissioning, adjustment and start up, chillers and fancoils (Wesper, Airwell, Ferroli, CIAT) and conditioners Split-systems (Samsung, LG, Daikin, Fuji, General, Mitsubishi, Toshiba, Panasonic), multi-Split (General, Mitsubishi, Panasonic) and VRF - systems (General, Mitsubishi, Hyundai). Samsung, LG, Daikin, Fuji, Sistemair, Danterm, VTS-clima, CIC, 2VV, Korf, NED, Carell, Siemens
E&I HVAC design of non-standard solution – replace fans and pumps motor with built-in VFD to separate motor and VFD - reduce issue to ZERO
E@I design and installation of all listed systems.
Caring out diagnostics, repair and preventive maintenance CM AND PM of all listed systems.
Huge modification of Barry Callebaut production in Moscow region. It was copy paste of South design – so during Russian winter time it have a problem of low temperature inside plant area and impossibility of chocolate fluid transfer. Together with Trane colleagues ad revers for heating HTF in chiller 1.2 and 0.6 MW Cooling power, design and installation of new AHU for transit, some process and filling areas.
Progress:
1. In the field of designing the project
Designing the project of supply and exhaust ventilation and air conditioning systems with recuperation in manufacturing zone including explosive zone.
Designing the project of supply and exhaust ventilation and air conditioning systems with recuperation in office in public swimming pools and drying systems, etc.
Designing the project of power supply of VRF – system;
Development of non-standard E&I solution of AHU and HTF pumps.
2. In the field of repairing:
Repairing of split systems, chillers (WESPER, TRANE), fancoil (AIRWELL, DAIKIN), supply and exhaust with recuperation;
Replacement of compressors, charging refrigerant, repair of electronic components.
There has been changed engine (Grundfos) with built-in variable frequency driver (MGE), both built-in supply and exhaust with heat recuperation (Danterm) by VFD (Siemens, Samsung etc). This cause shortest time of delivery of devices and repair cost.
3. In the field of Installation, adjustment and start in operation:
Installation, adjustment and start in operation of roof-top system “Technoclima”, with double stage of gas-heating and cooling systems.
work with PLC OVEN, Siemens, Regin, Carrier in AHU and Facility application.